We supply a selection of endoscopic spine products and instruments to NHS and Private Hospitals across the UK for endoscopic spine surgery. This type of surgery involves the process of an endoscope being inserted via a small incision within either the cervical (upper spine) or lumbar (lower spine). This method is known as ‘Minimally-Invasive Spine Surgery’ (MISS) due to its nature and provides patients with quicker recovery periods and less pain. Our ranges of innovative products include TESSYS® Instrument SystemCESSYS® instrument SystemEndoLIF® O-CageMultiZYTE® Instrument SystemSPASY Ballon Kyphoplasty System and joimax® Endoscopy SystemAll products can be purchased directly or hired on a contract basis with same-day delivery if required and all comply with current GS1 & traceability legislation.

  • Minimally Invasive Vertebral Compression Fracture (VCF) Treatment

    With over 20 years of commitment to procedural options and clinical evidence, Medtronic's balloon kyphoplasty empowers you to treat VCF patients with the unmatched innovations of a reliable, robust product platform. Treating VCF with Balloon Kyphoplasty Balloon kyphoplasty uses orthopedic balloons to restore vertebral height and correct angular deformity from VCF due to osteoporosis, cancer, or benign lesions. After reduction, the balloons are deflated and removed. The resulting cavity allows for a controlled deposition of bone cement to form an internal cast and stabilize the fracture. Key Features of the Kyphon™ Balloon Kyphoplasty Platform
    • 700 psi max rated inflation pressure, higher than previous 400 psi rated balloons.*
    • Cement resistance technique lets you deliver cement through one cannula while the contralateral balloon remains inflated to maintain fracture reduction.
    • Kyphon™ cement delivery system (CDS) lets you deliver cement from up to 48 inches away from the radiation source during a kyphoplasty procedure.
    * Kyphon Express™ II and Kyphon Xpander™ II ITBs have a maximum pressure rating of 700 psi while Kyphon Express™ II and Kyphon Xpander™ first generation ITBs have a maximum pressure rating of 400 psi.
  • Minimally Invasive Vertebral Compression Fracture (VCF) Treatment

    The Kyphon™ V Premium vertebroplasty platform is designed to facilitate maximum precision of high viscosity cement placement with minimal radiation exposure.1-4 Maximum Precision, Minimum Exposure With the Kyphon™ cement delivery system, the Kyphon V™ premium vertebroplasty system allows you to:1-3
    • Minimize radiation exposure2 by standing up to four feet away from the radiation source, which has been measured to reduce hand radiation exposure by 70% (compared to Kyphon™ bone filler device when measured with dosimeters under fluoroscopy)*
    • Stop cement flow instantly3 by pushing the quick release button to minimize the potential for cement extravasation

    * The mean radiation reduction at the hands was 77.79% (p<0.001). Based on an internal testing of 24 total cadaveric procedures (n=12 using Kyphon CDS and n=12 using Kyphon Bone Filler Device). Dosimeters were placed on the wrist and fingers to measure radiation when delivering bone cement into the vertebral body. Radiation result reported is based on adherence to the Directions for Use.

    1 Medtronic Data on File – Kyphon V Premium Vertebroplasty 2 Medtronic Data on File – Kyphon Cement Delivery System 3 Medtronic Data on File – Engineering Test Report 4 Medtronic Data on File – Kyphon Kurve